What a DICOM router does, in short
The short answer
A DICOM router receives studies from scanners or a PACS using the DICOM C-STORE service, looks at the header of each study (modality, body part, sending AE title, referring site, priority), applies routing rules, and sends the study on to one or more destinations, again by C-STORE. It queues studies when a destination is unreachable and retries, can fix header values so the receiving system files the study correctly, and can compress images losslessly for slower links. Teleradiology depends on it: it is how a hospital’s images reach an outside reading PACS without anyone pushing them by hand.
- 104DICOM’s well-known port (IANA “acr-nema”)
- 11112registered DICOM port, for systems without privileged ports
- 16 charsmaximum length of an AE title
Sources: DICOM PS3.8 · IANA port registry · DICOM PS3.5. Checked October 27, 2026.
How a DICOM router works, step by step
Step 01 of 06
Receive
A scanner or PACS opens a DICOM association with the router and sends each image with C-STORE. The DICOM Storage Service Class “allows one DICOM AE to send images, waveforms, reports, etc., to another” (PS3.4).
Step 02 of 06
Inspect
The router reads the DICOM tags: patient and accession number, modality, study description, body part, sending AE title and station.
Step 03 of 06
Decide
Rules pick the destination: for example all ED CT after 10 PM to the overnight reading group, mammograms to breast readers, everything to the archive. Many routers also have a default route for anything no rule matches.
Step 04 of 06
Adjust
If needed it rewrites values (such as adding a site prefix to the accession number) so the receiving system files the study correctly. The standard calls this attribute coercion. It can also re-encode images in a lossless transfer syntax such as lossless JPEG 2000.
Step 05 of 06
Forward
It opens associations to each destination and sends the study. If a link is down, the study waits in a queue and is retried, so nothing is lost.
Step 06 of 06
Confirm
Optionally it asks the destination for DICOM Storage Commitment, a promise to keep the images safely, and logs every transfer for audit.
Sources: DICOM PS3.4 (Storage, Storage Commitment, coercion) · PS3.5 (transfer syntaxes). Checked October 27, 2026.
The settings that matter
- AE title
- An Application Entity title “uniquely identifies a service or application on a specific system in the network” (PS3.8). It is up to 16 characters. Every sender and receiver must know the other’s AE title, IP address and port.
- Port
- DICOM recommends port 104, the well-known port registered at IANA as “acr-nema,” or 11112, IANA’s registered “dicom” port, when privileged ports are not available. DICOM over TLS has its own registered port, 2762 (“dicom-tls”) (IANA).
- Association
- Before any images move, the two systems negotiate an association: which kinds of objects will be exchanged and how they are encoded (PS3.7).
- C-ECHO
- The DICOM “ping.” It verifies end-to-end communication between two AEs and is the first test when a new route is set up.
- Transfer syntax
- How pixel data is encoded: uncompressed, or compressed losslessly (for example JPEG 2000 lossless) to save bandwidth without losing diagnostic information.
Security: TLS, VPNs and HIPAA
The HIPAA Security Rule requires technical measures “to guard against unauthorized access to electronic protected health information that is being transmitted over an electronic communications network” (45 CFR 164.312(e)(1)). Images leaving the hospital are protected in one of two ways:
DICOM over TLS
The DICOM connection itself is encrypted. The current DICOM secure transport profile requires TLS 1.2 and prefers TLS 1.3 (PS3.15 Annex B).
Site-to-site VPN
An encrypted tunnel between the hospital network and the reading group’s network carries ordinary DICOM and HL7 traffic. Common for teleradiology, and easy for hospital IT to audit.
Many sites use both. Either way, the router should log every study sent and received.
Orders travel alongside: HL7
Images are only half the picture. The reader also needs the order: who the patient is, what was ordered and why. That comes by HL7, not DICOM. In the IHE Scheduled Workflow profile, the ordering system places the order with an HL7 order message (ORM in HL7 v2.3.1, OMG/OMI in v2.5.1), the modality pulls its worklist, images are stored, and the finished report returns as an HL7 result message (ORU) (IHE Radiology Technical Framework). Many DICOM routers have an HL7 counterpart, an interface engine or HL7 router, so that the order and the images arrive at the reading PACS together and match on accession number.
When studies come from another enterprise with different patient IDs, IHE’s Import Reconciliation Workflow describes how to reconcile them with local patient and order data while keeping the original. For a fuller comparison of the two standards, see DICOM vs HL7 in radiology.
How a teleradiology group connects to your hospital
- 01
Agree the network path
A site-to-site VPN or DICOM over TLS between your network and the reading group’s, approved by your IT security team.
- 02
Exchange AE titles, IPs and ports
Both sides add each other as DICOM nodes and test with C-ECHO.
- 03
Set the routing rules
Which studies go out (for example ED and inpatient CT, MRI, ultrasound and X-ray during covered hours), which priors go with them, and what stays local.
- 04
Connect the orders
An HL7 order feed so each study arrives with its order, history and accession number.
- 05
Send reports back
Signed reports return by HL7 into your RIS, EHR or PACS, so your clinicians see them where they already look.
- 06
Test and monitor
Send test studies end to end, then watch the queue: a study stuck in a router queue is a delayed read.
Before you switch reading groups, read how to switch teleradiology providers; most of the work is in these routes.
DICOMweb: routing over HTTPS
Newer systems can also move images with DICOMweb, the web version of DICOM: STOW-RS to store, WADO-RS to retrieve and QIDO-RS to search, all over HTTPS (PS3.18). Many routers speak both, which helps when one end is a cloud PACS. More in what is PACS.
How it works with TeleRads
With TeleRads, orders come to us by HL7 and images by secure routing to our PACS. Signed reports go back into your system. We read on our PACS, and we set up HL7 and image routing with your IT team and walk them through every step, and our technology runs on SOC 2-compliant platforms. We sign a HIPAA BAA with every hospital, and our target is live in 30 days, with the IT connection running in parallel with credentialing. See how it works.
Questions
What is a DICOM router?
Software that receives medical images over DICOM, applies routing rules based on the study’s header, and forwards each study to one or more destinations, queuing and retrying if a destination is unreachable.
What is the difference between a PACS and a DICOM router?
A PACS stores and displays images for reading. A router only moves them: it receives, sorts and forwards studies between scanners, PACS, archives and outside readers.
What port does DICOM use?
Port 104 is DICOM’s well-known port (registered at IANA as acr-nema); 11112 is the registered DICOM port; DICOM over TLS uses 2762.
What is an AE title?
An Application Entity title, a name of up to 16 characters that identifies a DICOM application on the network. Each sender and receiver is configured with the other’s AE title, IP address and port.
Do you need a VPN for teleradiology?
Not always, but images in transit must be protected under the HIPAA Security Rule’s transmission-security standard, where encryption is an addressable specification. In practice that means a site-to-site VPN, DICOM over TLS, or both.
Does a DICOM router handle HL7?
Not by itself: HL7 orders and reports travel on a separate interface, often an HL7 router or interface engine running alongside the DICOM router, matched on accession number.